CGI International Ltd has been involved in clear fire glasses for over 15 years, initially in the UK with specially tempered glass. From experience, we know that even in a small territory like the UK, delivery times and logistics can be problematic. For an area the size of North America the problems are multiplied.

Pyroguard Clear Fire-Rated Glass uses 2 external faces of 1/8" float filled with a special resin which provides the following features:

  • 20/30 minute fire rating (no hose stream) for use in Steel and Wood doors, sidelites, transoms, borrowed lites and fire window frames.
  • Passes Positive Pressure test standards UL 10C, UBC 7-2 & UBC 7-4.
  • Tested by U.L. and Warnock Hersey.
  • Safety Rated to CPSC 16 CFR 1201 Category I (18" drop height) and ANSI Z97.1.
  • Temperature stable to 180 F without reaction.
  • For use internally and externally.
  • Clear, wireless and free from distortion.
  • Patterned options - 'Pyroguard Satin', 'Pyroguard Master' and 'Pyroguard Stippolyte' also available.
  • Can be cut from stock by normal laminated cutting methods.
  • Handy stock sizes 98" x 62", 5/16" thickness.
  • Price competitive.
  • Available throughout North America through Oldcastle Glass
    www.oldcastleglass.com

Pyroguard Clear, 5/16" (7.2mm) thick transparent laminated glazing for use in any flush wood cored doors or any steel-stiffened steel faced doors rated up to 20 minutes without hose stream. For use in Anemostat LoPro Vision Light Kit or proprietary steel door manufacturer's glazing bead.

Meeting CPSC 1201-98 Category I and 18" impact per ANSI-A97.1-84.

Listings:

Listed and labelled by Underwriters Laboratory, Inc (U.L.) and Warnock Hersey as follows

(a) Door Vision Panels, Transoms and Sidelites

ASTM E-152, Methods of Fire Tests of Door Assemblies
CAN4-S104 (ULC-S104), Standard Method for Fire Tests of Door Assemblies
CSFM 43.7, Standard Methods of Fire Tests of Door Assemblies
NFPA 252, Standard Methods of Fire Tests of Door Assemblies
UBC 7-2-94, Uniform Building Code Standard
UL 10(b), Fire Tests of Door Assemblies
UL 10©, Positive Pressure Fire Tests of Door Assemblies

(b) Fire Window Assemblies

ASTM E-163, Methods of Fire Tests of Fire Window Assemblies
CAN4-S106, Standard Method for Fire Tests of Window & Glass Block Assemblies
NFPA 257, Standard Method for Fire Tests of Fire Window Assemblies
UBC 7-4-94, Uniform Building Code Standard
UL 9, Fire Tests of Fire Window Assemblies

Maximum Allowable Sizes

Listing for 5/16 Clear Pyroguard® fire rated glass in the USA

Underwrites Laboratories

Sizes listed for 5/16 Clear Pyroguard® 20 minute fire rated glass (non hose-stream)

For full listing visit UL web site on www.ul.com

ITS Warnock Hersey

Sizes listed for 5/16 Clear Pyroguard® 20 minute fire rated glass (non hose-stream)

For full listing visit UL web site on www.etlsemko.com

Listed products are intended to be installed in accordance with NFPA 80 and the Manufacturers' instructions

Listed maximum sizes of glazing are based on sizes tested and may differ from those allowed by local codes. Dependant on the end use installation, local codes may require that additional criteria be met to address considerations such as radiant heat hazards and impact safety. Under such circumstances, the prior approval of the Authority having jurisdiction must be obtained unless conformance to relevant additional requirements is indicated within the individual listing.

Clearance between the edges of the glazing and the inside edge of the frame shall not exceed 1/8" unless otherwise noted in the individual listing or the manufacturer's installation instructions.

All glazing is identified by an etched mark or label bearing the U.L., WHI or ETL Certification Mark.

CSI Specifications - Click download for the Word (RTF) version of the leaflet
CSI Specifications - Click download for the Word (DOC) version of the leaflet

Download Literature - Click download for the PDF datasheet

 



Door & Hardwood InstituteUnderwriters LaboratoriesWarnock Hersey